Performance evaluation of gravity-driven membrane (GDM) systems in improving physicochemical and microbial water quality of highly turbid surface water and development of a site selection framework in Uganda
Performance evaluation of gravity-driven membrane (GDM) systems in improving physicochemical and microbial water quality of highly turbid surface water and development of a site selection framework in Uganda
Date
2026
Authors
Mumbere, Molcume
Journal Title
Journal ISSN
Volume Title
Publisher
Abstract
Access to safe drinking water remains a significant public health challenge in Uganda, particularly
in rural and peri-urban areas reliant on highly turbid surface water. Gravity-Driven Membrane
(GDM) technology offers a promising, low-energy solution for decentralized water supply;
however, its operational performance under consistently high influent turbidity (>50 NTU) and
the precise multi-criteria parameters for its optimal deployment in Uganda remain poorly
understood. This study addressed these gaps by evaluating GDM treatment performance using
highly turbid raw water from the Lubigi wetland (mean turbidity: 218.45 NTU), comparing the
efficiency of two distinct system configurations (the horizontally configured Aqua Cube and the
vertically configured Paul Water Pack) over an 11-week monitoring period, and developing a
siteselection framework. Experimental results demonstrated that GDM technology serves as a highly
effective mechanical barrier for turbidity removal, achieving a mean efficiency of 98.6% and
consistently producing an effluent below 1.5 NTU, well within the Uganda National Bureau of
Standards (UNBS EAS 12:2014) maximum limit of 5 NTU. Paired t-tests confirmed that GDM
filtration did not significantly alter Total Dissolved Solids (TDS) (p=0.892) or pH (p=0.418), the
mean effluent TDS remained stable at 285.8 mg/L (safely below the 700 mg/L UNBS threshold),
and pH values stabilized between 7.1 and 7.4 (adhering to the national standard range of 6.5–8.5).
In terms of microbiological water quality, the Aqua Cube unit achieved superior retention, yielding
a 1.1–1.3 log reduction of total coliforms (mean effluent: 163.87 CFU/100 mL), whereas the Paul
Water Pack achieved a 0.6–0.7 log reduction (mean effluent: 376.6 CFU/100 mL). Despite these
reductions, neither configuration independently eliminated total coliforms to meet the mandatory
national standard of 0 CFU/100 mL. Additionally, the study generated a comprehensive Decision
Support Framework to standardize and optimize future GDM deployment by integrating technical,
social, environmental and financial dimensions. In conclusion, GDM technology serves as a highly
effective primary treatment barrier for high-turbidity water. However, implementation must
include mandatory post-treatment disinfection to ensure public health safety.
The developed site selection framework provides a vital tool for policymakers to optimize GDM placement and
maximize project sustainability in resource-limited settings.
Description
A dissertation submitted to the Graduate School for the partial fulfillment of the requirements for the award of the Degree of Master of Science in Civil Engineering of Makerere University.
Keywords
Citation
Mumbere, M. (2026). Performance evaluation of gravity-driven membrane (GDM) systems in improving physicochemical and microbial water quality of highly turbid surface water and development of a site selection framework in Uganda. (Unpublished Master's Dissertation) Makerere University, Kampala, Uganda.