    Evaluation of thermal comfort and air quality of low-income housing in Kampala City, Uganda

    Thumbnail
    View/Open
    Research article (4.930Mb)
    Date
    2021
    Author
    Kajjoba, Derrick
    Kasedde, Kasedde
    Olupot, Peter W
    Lwanyaga, Joseph D
    Metadata
    Show full item record
    Abstract
    This paper presents the results of thermal comfort and air quality studies in naturally ventilated residential buildings in Kampala City, Uganda. Questionnaire surveys were used for obtaining occupant subjective thermal sensation votes. Indoor and outdoor measurements for air temperature (Ta), Mean Radiant Temperature (MRT), relative humidity, air speed, and air quality were done for seven buildings over fifteen days during the month of June 2019. DesignBuilder software was used to develop the reference building model and to simulate strategies for improvement of thermal comfort. Survey results showed that 67.8% of the respondents were comfortable with the indoor thermal environment. The indoor air temperature range was 22.7°C - 27.9°C which lies within the 80% acceptable limits set by ASHRAE 55. The measured indoor MRT range was 24.24°C - 25.57°C. Measured levels of indoor PM2.5 were double the World Health Organization recommended limits, while the levels of PM10 were thrice the recommended limits of ASHRAE 62.1. The CO2 concentrations were within the limits set by ASHRAE 62.1. The developed model predicted comfortable indoor conditions with a temperature range of 23.6°C - 25.3°C based on the 80% acceptable limits set by ASHRAE 55. The results show that majority of occupants preferred cooler temperatures during the day which is justified by the use of adaptive measures to obtain thermal comfort.
    URI
    https://doi.org/10.1016/j.enbenv.2021.05.007
    http://hdl.handle.net/10570/14432
    Collections
    • School of Engineering (SEng.) Collections

    DSpace 5.8 copyright © Makerere University 
    Contact Us | Send Feedback
    Theme by 
    Atmire NV
     

     

    Browse

    All of Mak IRCommunities & CollectionsTitlesAuthorsBy AdvisorBy Issue DateSubjectsBy TypeThis CollectionTitlesAuthorsBy AdvisorBy Issue DateSubjectsBy Type

    My Account

    LoginRegister

    Statistics

    Most Popular ItemsStatistics by CountryMost Popular Authors

    DSpace 5.8 copyright © Makerere University 
    Contact Us | Send Feedback
    Theme by 
    Atmire NV